Equipment we install
IQ System Controller 2
Microgrid interconnection and backup isolation.
Contact for pricing
- Service rating
- 200.0 A
- Continuous current
- 160.0 A
Specifications
| Electrical arrangement | Integrated distribution |
| Internal bus rating (A) | 200.0 |
| Electrical connections | grid: Grid, Grid side, 200.0 A maximum protection, Internal or external; backup_loads: Load, Backup side, 200.0 A maximum protection, External; pv: PV, Backup side, 80.0 A maximum protection, Internal; battery: Battery, Backup side, 80.0 A maximum protection, Internal; generator: Generator, Backup side, 80.0 A maximum protection, Internal |
| Model | EP200G101-M240US01 |
| Certification | UL1741; UL1741SA; UL1741SB; UL 1741 PCS CRD; UL1998; UL67; UL50E; CSA C22.2 No. 107.1; 47 CFR Part 15 Class B. Approved for use as service equipment in the United States. |
| Service current (A) | 200.0 |
| Continuous current (A) | 160.0 |
| Nominal AC voltage (V) | 240.0 |
| Short-circuit rating (kA) | 22.0 |
| Maximum OCPD (A) | 200.0 |
| Maximum PV port current (A) | 80.0 |
| Maximum battery port current (A) | 80.0 |
| Maximum generator port current (A) | 80.0 |
| AC phases | 1 |
| Poles | 2 |
| Frequency (Hz) | 60 |
| Warranty | 10 |
| Service entrance rated | Yes |
| Whole-home backup supported | Yes |
| Partial-home backup supported | Yes |
| Generator supported | Yes |
| Form factor | Enclosure |
| Neutral switching | Solid |
Description
200 A service‑entrance microgrid interconnection device with integrated distribution and neutral‑forming transformer. Provides grid isolation and breaker positions for PV, IQ Battery, and optional generator sources (up to 80 A each) with 160 A continuous current at 240 V split‑phase. UL1741 listed and supplied with a 10‑year limited warranty.