Equipment we install
IQ Meter Collar
Microgrid interconnection and backup isolation.
Contact for pricing
- Service rating
- 200.0 A
- Continuous current
- 200.0 A
Specifications
| Electrical arrangement | Inline isolator |
| Electrical connections | grid: Grid, Grid side, 200.0 A maximum protection, 200.0 A continuous, External; load: Load, Backup side, 200.0 A maximum protection, 200.0 A continuous, External |
| Model | MC-200-011-V01 |
| Certification | UL 414; CSA C22.2 No.115:2025; CFR 47 Part 15B; UL 1741 SA/SB (IEEE 1547:2018), multi-mode; Meets CA Rule 21, Puerto Rico PREPA, and Hawaiian Electric Industries (HEI) SRD V2.0 grid profiles |
| Service current (A) | 200.0 |
| Continuous current (A) | 200.0 |
| Nominal AC voltage (V) | 240.0 |
| Short-circuit rating (kA) | 22.0 |
| Maximum OCPD (A) | 200.0 |
| AC phases | 1 |
| Poles | 2 |
| Frequency (Hz) | 60 |
| Warranty | 15 |
| Service entrance rated | Yes |
| Whole-home backup supported | Yes |
| Partial-home backup supported | Yes |
| Form factor | Meter collar |
| Neutral switching | Solid |
Description
ANSI C12 Form 2S meter-collar adapter with an integrated microgrid interconnection device (MID) and energy meter. Service‑entrance rated for 200 A continuous on 120/240 V split‑phase systems and qualified to UL 1741 SA/SB grid profiles. Enables seamless transition between grid and backup power; 15‑year warranty.